So far, the TTLs for both A and AAAA records were not initialised,
resulting in exit relays sending back the value 60 to Tor clients. This
also impacts exit relays' DNS cache -- the expiry time for all domains
is set to 60.
This fixes <https://bugs.torproject.org/19025>.
The server-side clipping now clamps to one of two values, both
for what to report, and how long to cache.
Additionally, we move some defines to dns.h, and give them better
names.
In addition to the comments in the ticket, couple hidden service options have
been improved to clarify the maximum and minimum values they can be set to.
Closes#21058
Signed-off-by: David Goulet <dgoulet@torproject.org>
An operator couldn't set the number of introduction point below the default
value which is 3. With this commit, from 0 to the hardcoded maximum is now
allowed.
Closes#21033
Signed-off-by: David Goulet <dgoulet@torproject.org>
Our config code is checking correctly at DataDirectoryGroupReadable but then
when we initialize the keys, we ignored that option ending up at setting back
the DataDirectory to 0700 instead of 0750. Patch by "redfish".
Fixes#19953
Signed-off-by: David Goulet <dgoulet@torproject.org>
Let A = UseBridges
Let B = ClientUseIPv4
Then firewall_is_fascist_impl expands and simplifies to:
B || (!(A || ...) && A)
B || (!A && ... && A)
B || 0
B
The microdesc consensus does not contain any IPv6 addresses.
When a client has a microdesc consensus but no microdescriptor, make it
use the hard-coded IPv6 address for the node (if available).
(Hard-coded addresses can come from authorities, fallback directories,
or configured bridges.)
If there is no hard-coded address, log a BUG message, and fail the
connection attempt. (All existing code checks for a hard-coded address
before choosing a node address.)
Fixes 20996, fix on b167e82 from 19608 in 0.2.8.5-alpha.
It is no longer possible for the IPv6 preference options to differ from the
IPv6 usage: preferring IPv6 implies possibly using IPv6.
Also remove the corresponding unit test warning message checks.
(But keep the unit tests themselves - they now run without warnings.)
In order to help an HS operator knowing if the application configured behind
it is not working properly, add a log at warning level for the connection
refused or timeout case. This log will only be printed if a client connection
fails and is rate limited.
Closes#21019
Signed-off-by: David Goulet <dgoulet@torproject.org>
In 8a0ea3ee43 we added a
temp_service_list local variable to rend_config_services, but we
didn't add a corresponding "free" for it to all of the exit paths.
Fixes bug 20987; bugfix on 0.3.0.1-alpha.
Found using flake8 which gave the following output;
lintChanges.py:10:13: E225 missing whitespace around operator
lintChanges.py:25:1: E302 expected 2 blank lines, found 1
lintChanges.py:46:5: F841 local variable 'lines' is assigned to but never used
lintChanges.py:52:32: E228 missing whitespace around modulo operator
lintChanges.py:53:11: E201 whitespace after '('
lintChanges.py:56:41: E228 missing whitespace around modulo operator
Part of ticket 21096.