We don't want to allow general signals to be sent, but there's no
problem sending a kill(0) to probe whether a process is there.
Fixes bug 24198; bugfix on 0.2.5.1-alpha when the seccomp2 sandbox
was introduced.
When we close a connection via connection_close_immediately, we kill
its events immediately. But if it had been blocked on bandwidth
read/write, we could try to re-add its (nonexistent) events later
from connection_bucket_refill -- if we got to that callback before
we swept the marked connections.
Fixes bug 24167. Fortunately, this hasn't been a crash bug since we
introduced connection_check_event in 0.2.9.10, and backported it.
This is a bugfix on commit 89d422914a, I believe, which
appeared in Tor 0.1.0.1-rc.
Commit 56c5e282a7 suppressed that same log
statement in directory_info_has_arrived() for microdescriptors so do the same
for the descriptors. As the commit says, we already have the bootstrap
progress for this.
Fixes#23861
Signed-off-by: David Goulet <dgoulet@torproject.org>
evdns is allowed to give us unrecognized object types; it is allowed
to give us non-IPv4 answer types, and it is (even) allowed to give
us empty answers without an error.
Closes ticket 24097.
By convention, the torrc options that the user sets are
unchangeable. If we need to change them, we should be using a copy
that's stored in another field
To avoid trouble, I'm keeping DataDirectory as the name for the
field that the rest of Tor uses, and using DataDirectory_option for
the confparse-controlled field.
This commit also modernizes some older string handling code in the
DataDirectory normalization function.
Due to #23662 this can happen under natural causes and does not disturb
the functionality of the service. This is a simple 0.3.2 fix for now,
and we plan to fix this properly in 0.3.3.